SF-50 Fixed-hearth Incinerator

surefire_50
surefire_50ts-50s-ready-to-ship
SF-50 Robust, extremely reliable incinerator that is easy to site and simple to operate.  Full 2-second residence in the secondary combustion chamber ensures excellent emission control and environmental performance. 50kg/hour Manual Load General, Medical or Pathological Waste ...Read more

SF-50

Robust, extremely reliable incinerator that is easy to site and simple to operate.  Full 2-second residence in the secondary combustion chamber ensures excellent emission control and environmental performance.

  • 50kg/hour
  • Manual Load
  • General, Medical or Pathological Waste

Surefire Incinerators Logo




Surefire 50 features:

  • Heavy steel cylinder chambers for added strength
  • 1600° C (2912° F)-grade Super-duty refractory
  • High efficiency calcium silicate insulation
  • Automatic temperature controlled burners
  • Forced combustion air
  • Observation port with protective glass
  • Full sized load/ash removal door with safety interlock
  • Refractory-lined stack for longevity
  • Sterile ash residue less than 5% w/w
  • Pre-wired, pre-piped, pre-tested before shipment
  • User-friendly automatic control for maximum production with minimum fuel consumption

PrimaryChamber

Capacity: 35 ft3(2M3)

Thermal capacity: up to 1.2 MBTU/hr (700kw)

Number of burners: 1

Maximum operating temperature: 2732F(1500°C)

Normal operating temperature: 1300-1700F(750-950°C)

Hours of operation: 8-10 hours/day

Ash removal: Manual

Carbon content of ash: <5%

Quantity of Ash: 3% to 8%

 

Secondary Chamber

Residence time: 2 seconds

Maximum operating temperature: 2732°F (1500°C)

Normal operating temperature: 1550°F (850°C) minimum

 

Chimney

Height from floor level: 17ft (5.2m)minimum

Discharge temperature: 1550°F (850°C)

Exit velocity: 40ft/s(12m/s)

 

Burners

Primary burner max input: 1.0 MBTU/hr(290kW)

Secondary burner max input: 1.0 MBTU/hr(290kW)

Fuel: Natural gas, Propane or Diesel

 

Combustion Air System

Air introduction: Forced

Control: Manual

 

Electrical load:

Primary burner: 0.125kw

Secondary burner: 0.125kw

Combustion Air Fan: 5hp (3.7kw)

 

Weights:

Incinerator 11,000 lbs (5,000kgs)